{"product_id":"contec-ms200-nibp-simulator-blood-pressure-monitor-accuracy-simulation-test","title":"CONTEC MS200 NIBP Simulator Blood Pressure Monitor Accuracy Simulation Test","description":"\u003cp\u003e\n Introduction\n \u003cbr\u003e\n \u003cbr\u003e\n It is a multi - purpose test device for testing NIBP Monitor adopted Oscillometry. Concise and elegant in appearance, easy and convenient to operate, and it can generate the pressure up to 400mmHg (53.3 kPa) by the built-in air pump. With the functions of dynamic BP simulation under several conditions, static pressure calibration, automatic leak test and over-pressure relief test, which can quickly and accurately analyze each performance of NIBP Monitor.\n \u003cbr\u003e\n \u003cbr\u003e\n \u003cbr\u003e\n Functions\n \u003cbr\u003e\n \u003cbr\u003e\n 1)Pressure leak test\n \u003cbr\u003e\n 2)Over-pressure relief test\n \u003cbr\u003e\n 3)BP simulation under standard condition\n \u003cbr\u003e\n 4)BP simulation under patient condition\n \u003cbr\u003e\n 5)BP simulation under arrhythmia condition\n \u003cbr\u003e\n 6)BP simulation under respiratory interference condition\n \u003cbr\u003e\n 7)BP simulation of neonate\n \u003cbr\u003e\n 8)Wrist BP simulation\n \u003cbr\u003e\n 9)User-defined BP simulation\n \u003cbr\u003e\n 10)System setting function.\n \u003cbr\u003e\n 11)The parameters set can be stored.\n \u003cbr\u003e\n 12)ON\/OFF function\n \u003cbr\u003e\n 13)Dynamic BP simulation\n \u003cbr\u003e\n \u003cbr\u003e\n \u003cbr\u003e\n Performance\n \u003cbr\u003e\n \u003cbr\u003e\n BP simulation range:\n \u003cbr\u003e\n Systolic pressure: 2.7 kPa (20 mmHg) ~ 40.0 kPa (300 mmHg)\n \u003cbr\u003e\n Diastolic pressure: 1.3kPa (10 mmHg) ~ 33.3 kPa (250mmHg)\n \u003cbr\u003e\n Pulse volume: 0.1 cc ~ 2.4 cc\n \u003cbr\u003e\n HR range: 30 bpm ~ 250 bpm; pulse volume \u0026gt; 2.00 cc, maximum HR: 200 bpm\n \u003cbr\u003e\n HR accuracy: ± 1 bpm (except patient condition, arrhythmia and respiratory disturbance)\n \u003cbr\u003e\n Under patient condition:\n \u003cbr\u003e\n Weak pulse, tachycardia, obese, geriatric: ±（preset value 1%+1）bpm\n \u003cbr\u003e\n Moderate exercise: ±（preset value 1.5%+1）bpm\n \u003cbr\u003e\n Strenuous exercise: ±（preset value 3%+1）bpm\n \u003cbr\u003e\n Pressure measurement:\n \u003cbr\u003e\n Range: 0kPa (0 mmHg) ~ 53.3 kPa (400 mmHg)\n \u003cbr\u003e\n Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.1 psi\n \u003cbr\u003e\n Accuracy:\n \u003cbr\u003e\n 0 kPa (0 mmHg) ~ 40.0 kPa (300 mmHg), ± (0.5 % of reading + 0.1) kPa or ± (0.5% of reading +1) mmHg\n \u003cbr\u003e\n 40.1 kPa (301 mmHg) ~ 53.3 kPa (400mmHg), ± 2% of reading\n \u003cbr\u003e\n Pressure leak test\n \u003cbr\u003e\n Generate a pressure up to 400 mmHg by the built-in air pump. It always displays the peak pressure and the real-time pressure. Leak rate is displayed after 10 seconds.\n \u003cbr\u003e\n Over-pressure relief test\n \u003cbr\u003e\n Generate a pressure up to 400 mmHg by the built-in air pump, it displays peak pressure.\n \u003cbr\u003e\n Pressure source:\n \u003cbr\u003e\n Output range: 6.7 kPa (50 mmHg) ~ 53.3 kPa(400 mmHg)\n \u003cbr\u003e\n Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.1 psi\n \u003cbr\u003e\n Deviation between target pressure and actual pressure: ± 1.3 kPa (± 10 mmHg) in range of 13.3 kPa (100 mmHg) ~ 53.3 kPa (400 mmHg) with a minimum volume of 300 cc\n \u003cbr\u003e\n Airtightness\n \u003cbr\u003e\n Total airtightness: \u0026lt; 0.3 kPa\/min (2.25 mmHg\/min) under “OFF” state\n \u003cbr\u003e\n Airtightness of built-in cuff: 0.27 kPa\/min (2 mmHg\/min)\n \u003cbr\u003e\n BP simulation preset value configuration table\n \u003cbr\u003e\n \u003cbr\u003e\n \u003cbr\u003e\n BP simulation BP preset value BP HR Pulse volume\n \u003cbr\u003e\n Standard BP simulation #1 120\/80（93） 80bpm 0.68cc\n \u003cbr\u003e\n #2 150\/100（116） 0.65cc\n \u003cbr\u003e\n #3 200\/150（166） 0.60cc\n \u003cbr\u003e\n #4 255\/195（215） 0.55cc\n \u003cbr\u003e\n #5 60\/30(40) 0.75cc\n \u003cbr\u003e\n #6 80\/50（60） 0.71cc\n \u003cbr\u003e\n #7 100\/65（76） 0.69cc\n \u003cbr\u003e\n BP simulation under patient condition\n \u003cbr\u003e\n Healthy heart 120\/80(93) 75bpm 0.68cc\n \u003cbr\u003e\n Weak Pulse 110\/80(90) 95bpm 0.50cc\n \u003cbr\u003e\n Mild Exercise 140\/90(106) 120bpm 1.00cc\n \u003cbr\u003e\n Strenuous Exer 140\/90(106) 162bpm 1.40cc\n \u003cbr\u003e\n Obese 120\/80(93) 90bpm 0.50cc\n \u003cbr\u003e\n Geriatric 150\/110(123) 95bpm 0.40cc\n \u003cbr\u003e\n Tachycardia 120\/105(110) 130bpm 0.40cc\n \u003cbr\u003e\n Bradycardia 120\/60(80) 45bpm 1.10cc\n \u003cbr\u003e\n BP simulation under arrhythmia condition\n \u003cbr\u003e\n Premature Atrial Contraction1 138\/53(81) 80bpm 0.70cc\n \u003cbr\u003e\n \u003cbr\u003e\n \u003cbr\u003e\n Premature Atrial Contraction2 144\/64(90) 83bpm\n \u003cbr\u003e\n Premature Ventricular Contraction 118\/61(80) 83bpm\n \u003cbr\u003e\n Atrial Fibrillation and PVC 139\/72(94) 91bpm\n \u003cbr\u003e\n \u003cbr\u003e\n \u003cbr\u003e\n BP simulation under respiratory interference condition\n \u003cbr\u003e\n spontaneous breathing1 138\/65(89) 104bpm 0.60cc\n \u003cbr\u003e\n spontaneous breathing2 149\/65(93) 105bpm\n \u003cbr\u003e\n spontaneous breathing3 112\/47(68) 86bpm\n \u003cbr\u003e\n controlled breathing 132\/44(73) 98bpm\n \u003cbr\u003e\n BP simulation of neonate\n \u003cbr\u003e\n #1 35\/15(22) 120bpm 0.11cc\n \u003cbr\u003e\n #2 60\/30(40) 0.10cc\n \u003cbr\u003e\n #3 80\/50(60)\n \u003cbr\u003e\n #4 100\/70(80)\n \u003cbr\u003e\n BP simulation of wrist cuff\n \u003cbr\u003e\n #1 120\/80(93) 80bpm 0.50cc\n \u003cbr\u003e\n #2 160\/100(120)\n \u003cbr\u003e\n #3 80\/55(63)\n \u003cbr\u003e\n User-defined BP simulation[1] - - - -\n \u003cbr\u003e\n Note[1]：Support 9 user-defined BP simulation modes. The following parameters can be defined by users:2.3.1.The value of diastolic pressure should be lower than systolic pressure, pulse volume and HR can not be set to the highest values (e.g., pulse volume ≤ 2.00cc, HR: 250 bpm; pulse volume \u0026gt; 2.00cc, HR: 200bpm).\n \u003cbr\u003e\n \u003cbr\u003e\n \u003cbr\u003e\n Accessories\n \u003cbr\u003e\n \u003cbr\u003e\n One User Manual\n \u003cbr\u003e\n Two fuses\n \u003cbr\u003e\n One power cord\n \u003cbr\u003e\n \u003cbr\u003e\n \u003cbr\u003e\n Physical characteristic\n \u003cbr\u003e\n \u003cbr\u003e\n Display: 4.3\" 65 K color LCD display\n \u003cbr\u003e\n Power supply: AC100 ~ 240 V 50\/60 Hz, \u0026lt;60 VA\n \u003cbr\u003e\n Environment temperature: + 5 ℃ ~ + 40 ℃\n \u003cbr\u003e\n Relative humidity: \u0026lt; 90 %, non-condensing\n \u003cbr\u003e\n Altitude: ≤ 3000 m\n \u003cbr\u003e\n Atmospheric pressure: 80 kPa ~ 106 kPa\n \u003cbr\u003e\n Dimension: 207 (L) × 220 (W) × 121 (H) mm\n \u003cbr\u003e\n Weight: about 2.1 kg \n \u003cbr\u003e\n\u003c\/p\u003e","brand":"FLIPSTYLEZLLC","offers":[{"title":"MS200","offer_id":50764394627305,"sku":"CJZN1712712-MS200","price":6019.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0782\/4624\/8681\/files\/e6112e86-47ca-4897-aea7-c75ad2dd92a9.jpg?v=1775001433","url":"https:\/\/themodernmanor.com\/products\/contec-ms200-nibp-simulator-blood-pressure-monitor-accuracy-simulation-test","provider":"The Modern Manor","version":"1.0","type":"link"}